| Motor de Búsqueda de Datasheet de Componentes Electrónicos |
|
MMA8652FC Datasheet(PDF) 42 Page - NXP Semiconductors |
|
|
|||||||||||||||||||||||||||||
MMA8652FC Datasheet(HTML) 42 Page - NXP Semiconductors |
|
42 / 65 page ![]() MMA8652FC Sensors 42 Freescale Semiconductor, Inc. 6.9 Transient configuration and status registers For more information about the uses of the transient function, see application note AN4083, Data Manipulation and Basic Settings for Xtrinsic MMA865xFC Accelerometers. This Transient (HPF) acceleration detection function is similar to the motion detection function, except that high-pass filtered data is compared. There is an option to disable the high-pass filter through the function. In this case, the behavior is the same as the motion detection. This allows for the device to have two motion detection functions. 6.9.1 0x1D: Transient_CFG register The transient detection mechanism can be configured to raise an interrupt when the magnitude of the high-pass filtered acceleration threshold is exceeded. The TRANSIENT_CFG register is used to enable the transient interrupt generation mechanism for the three axes (X, Y, Z) of acceleration. There is also an option to bypass the high-pass filter. When the high-pass filter is bypassed, the function behaves similar to the motion detection. Table 58. 0x1D TRANSIENT_CFG register (Read/Write) Back to Register Address Map Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 — — — ELE ZTEFE YTEFE XTEFE HPF_BYP Table 59. TRANSIENT_CFG register Bit(s) Field Description Notes 7–5 — Could be 0 or 1. 4ELE Transient event flags are latched into the TRANSIENT_SRC register. Reading of the TRANSIENT_SRC register clears the event flag. 0 Event flag latch disabled (default) 1 Event flag latch enabled 3 ZTEFE Event flag enable for Z-transient acceleration greater than a transient threshold event. 0 Event detection disabled (default) 1 Raise event flag on measured acceleration delta value that is greater than a transient threshold. 2YTEFE Event flag enable for Y-transient acceleration greater than a transient threshold event. 1XTEFE Event flag enable for X-transient acceleration greater than a transient threshold event. 0 HPF_BYP Bypass high-pass filter 0 Data to transient acceleration detection block is through HPF (default) 1 Data to transient acceleration detection block is NOT through HPF (similar to motion detection function) |
|
Enlace URL |
| ¿ALLDATASHEET es útil para Ud.? [ DONATE ] |
Todo acerca de Alldatasheet | Publicidad | Contáctenos | Política de Privacidad | Enlace a la hoja de datos | Intercambio de Enlaces | Lista de Fabricantes All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |