| Motor de Búsqueda de Datasheet de Componentes Electrónicos |
|
TDA9112 Datasheet(PDF) 24 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
TDA9112 Datasheet(HTML) 24 Page - STMicroelectronics |
|
24 / 51 page ![]() TDA9112 24/51 Note 50: With exception of HDUTY and BREF adjustments data that can take effect instantaneously if switches HDutySyncV and B+SyncV are at 0 respectively. Note 51: In Read Mode, the device always outputs data of the status register, regardless of sub address previously selected. Note 52: The TV, TH, TVM and THM bits are for testing purposes and must be kept at 0 by application. Description of I2C Bus switches and flags Write-to bits Sad00/D7 - HDutySyncV Synchronization of internal application of Hori- zontal Duty cycle data, buffered in I2C Bus latch, with internal discharge of Vertical oscillator 0: Asynchronous mode, new data applied with ACK bit of I2C Bus transfer on this sub address 1: Synchronous mode Sad02/D7 - HMoiré Horizontal Moiré characteristics 0: Adapted to an architecture with EHT gener- ated in deflection section 1: Adapted to an architecture with separated deflection and EHT sections Sad03/D7 - B+SyncV Same as HDutySyncV, applicable for B+ refer- ence data Sad04/D7 - HDyCorTr Tracking of Horizontal Dynamic Correction waveform amplitude with Horizontal Size at ad- justment and EHT variation (voltage of HEHTIn). 0: Not active 1: Active Sad05/D7 - HDyCorPh Phase of start of Horizontal Dynamic Correction waveform (and B+ drive if in internal sawtooth configuration) in relation to horizontal flyback pulse. 0: Start of the flyback 1: Middle of the flyback 11 Reserved PCAC (Pin cushion asymmetry correction) 100 000 0 12 Reserved PARAL (Parallelogram correction) 100 000 0 13 Reserved TCAC (Top corner asymmetry correction) 100 000 0 14 Reserved BCAC (Bottom corner asymmetry correction) 100 000 0 15 VDyCorPol 0:” ∪” VDC-AMP (Vertical dynamic correction amplitude) 100 000 0 16 XRayReset 0: No effect 1: Reset VSyncAuto 1:On VSyncSel 0:Comp 1:Sep SDetReset 0: No effect 1: Reset 0 PLL1Pump 1: Fast 0: Slow PLL1InhEn 1:On HLockEn 1:On 17 TV 0:Off(52) TH 0:Off(52) TVM 0:Off(52) THM 0: Off(52) BOHEdge 0: Falling HBOutEn 0: Disable VOutEn 0: Disable BlankMode 1: Perm. READ MODE (SLAVE ADDRESS = 8D) XX (51) HLock 0: Locked 1: Not locked VLock 0: Locked 1: Not lock. XRayAlarm 1: On 0: Off Polarity detection Sync detection HVPol 1: Negative VPol 1: Negative VExtrDet 0: Not det. HVDet 0: Not det. VDet 0: Not det. Sad D7 D6D5 D4 D3D2 D1D0 |
|
Enlace URL |
| ¿ALLDATASHEET es útil para Ud.? [ DONATE ] |
Todo acerca de Alldatasheet | Publicidad | Contáctenos | Política de Privacidad | Enlace a la hoja de datos | Intercambio de Enlaces | Lista de Fabricantes All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |