| Motor de Búsqueda de Datasheet de Componentes Electrónicos |
|
3UG3501 Datasheet(PDF) 103 Page - List of Unclassifed Manufacturers |
|
|
|||||||||||||||||||||||||||||
3UG3501 Datasheet(HTML) 103 Page - List of Unclassifed Manufacturers |
|
103 / 114 page ![]() 3TK28 Safety Relays 7/103 Siemens LV 1 T · 2006 With electronic enabling circuits ■Technical specifications 1) Electrical equipment for furnaces. VDE certificate for 3TK28 41 and 3TK28 42 is available. 2) For relay outputs, use a fuse link: LV HRC Type 3NA, DIAZED Type 5SB, NEOZED Type 5SE: 6 A (weld-free protection at IK = 1 kA). 3) For instantaneous output. 4) When the cascading input is supplied from A1, the maximum response time is applicable to an external EMERGENCY-STOP. 5) The drivers are not supplied, internal supply bridging only. SELV/PELV power supply unit buffered. Type 3TK28 40 3TK28 41 3TK28 42 3TK28 45 Standards EN 60204-1 (VDE 0113 Part 1), EN ISO 12100, EN 954-1, IEC 61508, DIN VDE 01161) Category acc. to EN 954-1 3 4 4 4 Test certificates TÜV, UL, CSA Rated insulation voltage Ui • For control circuit V 50 50 50 50 • For outputs V 50 50 50 50/300 Rated impulse withstand voltage Uimp • For control circuit V 500 500 500 500 • For outputs V 500 500 500 500/2000 Operating range • DC operation 0.9 ... 1.15 × Us Rated operational currents Ie acc. to IEC 60947-5-1 • Ie/AC-15 at 115 V A -- -- -- 2 at 230 V A -- -- -- -- • Ie/ DC-13 at 24 V A 0.5 1.5 1.5 1.5 Short-circuit protection Short-circuit proof Short-circuit proof2) Electrical endurance Unlimited, because switched electronically Operating frequency z in operating cycles/h during normal duty 1/h 3000 Response time • Monitored start ms 125 60 60 60 • Autostart ms 250 60 60 60 release time • For EMERGENCY-STOP ms 30 45 453)/0.05 ... 300 s (adjustable) 453)/0.05 ... 300 s (adjustable) • For supply failure ms 25 1004) 1004) 100 Recovery time • For EMERGENCY-STOP ms 20 400 400 400 • For supply failure s 0.02 max. 7 max. 7 max. 7 Bridging of supply failures ms 255) 254)5) 254)5) 255) Minimum command duration • EMERGENCY-STOP ms 20 25 30 30 •ON button s 0.02 0.2 ... 5 0.2 ... 5 0.2 ... 5 Simultaneity ms Conductor cross-sections Screw-type connection • Finely stranded with end sleeve mm2 2 × (0.5 ... 1.5), 1 × (0.5 ... 2.5) • Solid mm2 2 × (0.5 ... 2.5), 1 × (0.5 ... 4) • Tightening torque Nm 0.8 ... 1.2 Spring-loaded terminals (1 or 2 conductors can be connected) • Solid mm2 2 × (0.25 ... 1.5) • Finely stranded with end sleeve mm2 2 × (0.25 ... 1.0) • Finely stranded without end sleeve mm2 2 × (0.25 ... 1.5) • AWG conductors, solid or stranded 2 × AWG 24 ... 16 Permissible ambient temperature • During operation °C –25 ... +60 • During storage °C –40 ... +80 Degree of protection acc. to EN 60529 • Enclosures IP40 • Terminals IP20 Touch protection acc. to DIN VDE 0106 Part 100 Finger-safe Shock resistance • Sinewave g/ms 8/10 and 15/5 Permissible mounting position Any |
|
Enlace URL |
| ¿ALLDATASHEET es útil para Ud.? [ DONATE ] |
Todo acerca de Alldatasheet | Publicidad | Contáctenos | Política de Privacidad | Enlace a la hoja de datos | Intercambio de Enlaces | Lista de Fabricantes All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |