Back Button 3UG3501 Datasheet HTML 102Page - List of Unclassifed Manufacturers 3UG3501 Datasheet HTML 103Page - List of Unclassifed Manufacturers 3UG3501 Datasheet HTML 104Page - List of Unclassifed Manufacturers 3UG3501 Datasheet HTML 105Page - List of Unclassifed Manufacturers 3UG3501 Datasheet HTML 106Page - List of Unclassifed Manufacturers 3UG3501 Datasheet HTML 107Page - List of Unclassifed Manufacturers 3UG3501 Datasheet HTML 108Page - List of Unclassifed Manufacturers 3UG3501 Datasheet HTML 109Page - List of Unclassifed Manufacturers 3UG3501 Datasheet HTML 110Page - List of Unclassifed Manufacturers Next Button
Zoom Inzoom in Zoom Outzoom out
 106 / 114 page
background image
3TK28 Safety Relays
With relay enabling circuits
7/106
Siemens LV 1 T · 2006
■Technical specifications
1) Only applicable for instantaneous enabling contacts; Category 3 applies
for time-delayed contacts.
2) Signaling circuit for 3TK28 21 = 6 A.
3) Other fuses on request.
4) Instantaneous/time-delayed enabling contacts.
5) 2 A applies to enabling contacts 13/14.
6) At 24 V AC: 300 ms.
7) At 115, 230 V AC: 300 ms.
8) At 115, 230 V AC: max. 200 ms.
9) At 115, 230 V AC: max. 80 ms.
Type
3TK28 21 3TK28 22 3TK28 23 3TK28 24 3TK28 30
3TK28 25 3TK28 27,
3TK28 28
3TK28 34 3TK28 35
Standards
EN 60204-1 (VDE 0113 Part 1), EN ISO 12100, EN 954-1
Also EN 574
Test certificates
BG, SUVA, UL, CSA
Category
• Acc. to EN 954-1
3
4
4
3
As basic
unit
4
41)
4
As basic
unit
• Acc. to EN 574
--
--
--
--
--
--
Type III C
Rated insulation voltage Ui
V
300
Degree of pollution
3
Overvoltage category acc. to EN 60664
III
Rated impulse withstand voltage Uimp
kV
4
Rated power of coils
DC/AC operation at 1.0 × Us
W
1.5
3
4
3
Operating range of the coils
• AC operation
0.85 ... 1.1 × Us
0.85 ... 1.1 × Us
• DC operation
0.85 ... 1.2 × Us
0.85 ... 1.1 × Us
Continuous thermal current Ith
A
5
6
5
6
5
Continuous thermal current Ith
for 2 to 4 enabling contacts (FK)
• At AT 70 °C
A
5
4
5
4
• At AT 60 °C
A
6
5
6
5
• At AT 50 °C
A
6
5
6
5
Rated operational currents Ie
acc. to IEC 60947-1
• Ie / AC-15
at 115 V
A
5
6
5/24)
6
5/25)
at 230 V
A
5
6
5/24)
6
5/25)
• Ie / DC-13
at 24 V
A
5
6
5/24)
6
5/25)
Short-circuit protection
Fuse inserts LV HRC Type 3NA, DIAZED Type 5SB, NEOZED Type 5SE: 6 A
(weld-free protection at Ik = 1 kA)
3)
gL/gG operational class 6 A (slow), quick 10 A2)
Mechanical endurance
10 million operating cycles
Electrical endurance at Ie
100000 operating cycles
Switching frequency
1000/h on loading with Ie
Response time
ms
ˆ 308)
ˆ 100
ˆ 50
• Monitored start
ms
--
--
ˆ 30
--
--
ˆ 25
ˆ 80
--
--
• Autostart
ms
ˆ 2006)
ˆ 100
--
ˆ 2006)7) --
ˆ 150
ˆ 80
--
--
Release time
ms
ˆ 20
ˆ 50
• For EMERGENCY-STOP
ms
ˆ 200
ˆ 80
ˆ 20
ˆ 200
–
ˆ 25
ˆ 25
--
--
• For supply failure
ms
ˆ 200
ˆ 100
ˆ 150
ˆ 200
ˆ 259)
ˆ 350
ˆ 100
--
--
Recovery time
˜ 250
˜ 250
• For EMERGENCY-STOP
ms
˜ 200
˜ 200
˜ 400
˜ 200
--
˜ 200
After time
has elapsed
--
--
• For supply failure
ms
˜ 200
˜ 200
˜ 600
˜ 200
˜ 100
˜ 500
˜ 1 s
--
--
Bridging of supply failures
ms
60
30
80
60
35
100
30
40
40
Minimum command duration
•EMERGENCY-STOP
ms
˜ 200
˜ 25
˜ 25
˜ 2007)
--
˜ 25
˜ 25
--
--
• ON button
ms
˜ 150
˜ 40
˜ 25
˜ 1507)
--
˜ 25
˜ 25
--
--
Simultaneity
ms
Š
500
Conductor cross-sections
Screw-type connection
• Finely stranded with end sleeve
mm2 2 × (0.5 ... 1.5), 1 × (0.5 ... 2.5)
• Solid
mm2 2 × (0.5 ... 2.5), 1 × (0.5 ... 4)
• Tightening torque, M 3.5 screw
Nm
0.8 ... 1.2
Spring-loaded terminals
(1 or 2 conductors can be connected)
• Solid
mm2 2 × (0.25 ... 1.5)
• Finely stranded with end sleeve
mm2 2 × (0.25 ... 1.0)
• Finely stranded without end sleeve
mm2 2 × (0.25 ... 1.5)
• AWG conductors, solid or stranded
2 × AWG 24 ... 16
Permissible ambient temperature
• During operation
°C
–25 ... +60 (suitable for butt-mounting; 70 °C possible with restrictions)
• During storage
°C
–40 ... +80
Degree of protection acc. to EN 60529
• Enclosures
IP40
IP20
• Terminals
IP20
IP20
Touch protection acc. to VDE 0106
Finger-safe
Shock resistance, half-sine acc. to IEC 60068
8 g/10 ms
Permissible mounting position
Any
2 FK
3 FK
4 FK
43.5
3
4.5
4
3.5
54.5
4



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100  ...More


Datasheet Descarga

Go To PDF Page


Enlace URL



¿ALLDATASHEET es útil para Ud.?  [ DONATE ] 

Todo acerca de Alldatasheet   |   Publicidad   |   Contáctenos   |   Política de Privacidad   |   Enlace a la hoja de datos    |   Intercambio de Enlaces   |   Lista de Fabricantes
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com