51 / 91 page ![]() ZIOL2xxx – IC Family IO-Link compliant HV Line Driver IC Family Data Sheet January 31, 2012 © 2012 Zentrum Mikroelektronik Dresden AG — Rev. 2.2.1 All rights reserved. The material contained herein may not be reproduced, adapted, merged, translated, stored, or used without the prior written consent of the copyright owner. The information furnished in this publication is PRELIMINARY and subject to changes without notice. 51 of 90 Figure 3.17 Over-Temperature Lock Control Comparator 8 Peak values 8 Over- Temperature Counter (8bit) AND count OVT Counter == Assert_time AND 8 set To register IRQ_STATUS Enables time based lock reset OVT_TIME_BASE [6:5] 0b00: 200 ns 0b01: 1 ms 0b10: 8 ms 0b11: 16 ms 2 rst 1 1 Over-Temperature Counter Count-up: if input signal count ==1 Count-down: if input signal count == 0 - no overrun - no underrun Counter reset with - write access to MON_RST_COUNTER [17] Data = 0bxxxxxxx1 -0 1 transition of OVT_EN From Over-Temperature detector SPI OVT_LOCK_TIME OVT_LOCK_TIME [05] >C< 0 7 bit reset 1 6 5 4 3 2 1 1 1 1 1 0 1 0 r / w MON_OVT_PEAK MON_OVT_PEAK [25] >S< 0 7 bit reset 0 6 5 4 3 2 1 0 0 0 0 0 0 0 r / rst OVT_EN OVT_LOCK_EN OVT_LOCK_TIME_RST OVT_TBASE reseved OVT_PFD_CTRL [09] >C< 0 7 bit reset 0 6 5 4 3 2 1 0 0 0 0 0 0 0 r / w LINE_FAULT_EN UNDER_VOLTAGE_EN 8 OVT_ASSERT_TIME OVT_ASSERT_TIME [08] >C< 0 7 bit reset 1 6 5 4 3 2 1 1 1 1 1 0 1 0 r / w Lock counter 8 clear AND 2 Power Fail Detector The Lock caused by an over-temperature displays that the die temperature has reached a critical level. That forces a self protecting save state, it causes disabling the COM and the AUX channel by turning off all the HV driver output stages (Figure 3.17). The IC configuration allows disabling the lock mode operation for overload exceptions from both channels (COM/AUX) and the exception from the die over-temperature detector. Since the lock mode operation prevents the IC to be destroyed due to physical stress situation, the disabling is not recommended or shall be done with particular caution only. Disabled lock mode operations for the above mentioned building blocks will prevent generating the related contribution to the interrupt signal at the INT_L pin. However, those exceptions can be retrieved by reading the status register MON_STAT[20] (refer to chapter 3.3.9 and/or Figure 3.18). Not depending on the lock mode operation the IC allows retrieving diagnostic information about the duration of an exception (peak values). The corresponding IC configuration that is required for retrieving such diagnostic data is illustrated above figures (Figure 3.15, Figure 3.16, and Figure 3.17). |
|
Enlace URL |
| ¿ALLDATASHEET es útil para Ud.? [ DONATE ] |
Todo acerca de Alldatasheet | Publicidad | Contáctenos | Política de Privacidad | Enlace a la hoja de datos | Intercambio de Enlaces | Lista de Fabricantes All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |