| Motor de Búsqueda de Datasheet de Componentes Electrónicos |
|
DA9072 Datasheet(PDF) 42 Page - Dialog Semiconductor |
|
|
|||||||||||||||||||||||||||||
DA9072 Datasheet(HTML) 42 Page - Dialog Semiconductor |
|
42 / 113 page ![]() DA9072 Ultra-Low Quiescent Current PMIC Datasheet Revision 3.0 14-Jun-2021 CFR0011-120-00 42 of 113 © 2021 Dialog Semiconductor A fault triggered power cycle also disables VDD_SYS, creating a complete power system restart (a host or user-initiated power cycle does not disable VDD_SYS). Table 29: Power Cycle Faults Power Cycle Fault Triggers 0x0013 Register Bit I2C Selectable Register Reset Battery Temp Sense HOT 0 YES YES Thermal Shutdown (OVT) NA Always On YES VBAT UVLO (in Active Battery mode) NA Always On YES VDD_SYS UVLO NA Always On YES There are also three power cycle faults associated with the buck, listed in Table 30. Any of these faults cause an immediate power cycle. Buck faults do not re-load the OTP register values and only the buck restarts after a buck fault power cycle. Table 30: BUCK Power Cycle Faults Power Cycle Fault Triggers 0x0013 Register Bit I2C Selectable Register Reset BUCK OCP 4 YES NO BUCK OVP NA Always On NO BUCK UVP 6 YES NO 4.7 Standalone Mode The DA9072 can operate without I2C communication using external resistors to program three settings. Fast charge current, input current limit, and termination and pre-charge current can be set by external resistors at the ITER_CHG, ILIM_PWR and ILIM_CHG pins, respectively. This feature is enabled by the RMEAS_EN bit (register 0x0020 [1]). Whenever VDD_PWR is plugged-in, these three external resistors are evaluated and the control registers are set appropriately. If the pins are connected to ground the internal register values are used. If used, all three resistors must be installed. If any of the three pins are grounded all three currents are determined by their respective register values. The specification of RMEAS_EN register is described in Table 31. Table 31: Enabling External Resistor Setting Mode RMEAS_EN (0x0020 [1]) External Resistance [ Ω] Setting 0 N/A Register settings used 1 0 Register settings used 1 > 0 Calculated from external resistance 4.7.1 Termination and Pre-Charge Current Programming The pre-charge (ICHG_PRE) and termination (ITER) currents are the same value and set with the same resistor. When using the external resistor setting method, they can be set to 5 %, 10 %, 15 %, or 20 % of the fast charge current, ICHG. |
|
Enlace URL |
| ¿ALLDATASHEET es útil para Ud.? [ DONATE ] |
Todo acerca de Alldatasheet | Publicidad | Contáctenos | Política de Privacidad | Enlace a la hoja de datos | Intercambio de Enlaces | Lista de Fabricantes All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |