12 / 20 page ![]() M48T212A 12/20 TIMEKEEPER REGISTERS The M48T212A offers 16 internal registers which contain TIMEKEEPER, Alarm, Watchdog, Flag, and Control data. These registers are memory lo- cations which contain external (user accessible) and internal copies of the data (usually referred to as BiPORTTM TIMEKEEPER cells). The external copies are independent of internal functions except that they are updated periodically by the simultaneous transfer of the incremented internal copy. TIMEKEEPER and Alarm Registers store data in BCD. Control, Watchdog and Flags Registers store data in Binary Format. CLOCK OPERATIONS Reading the Clock Updates to the TIMEKEEPER registers should be halted before clock data is read to prevent reading data in transition. Because the BiPORT TIME- KEEPER cells in the RAM array are only data reg- isters, and not the actual clock counters, updating the registers can be halted without disturbing the clock itself. Updating is halted when a ’1' is written to the READ bit, D6 in the Control Register (8h). As long as a `1' remains in that position, updating is halted. After a halt is issued, the registers reflect the count; that is, the day, date, and time that were current at the moment the halt command was is- sued. All of the TIMEKEEPER registers are updated si- multaneously. A halt will not interrupt an update in progress. Updating occurs 1 second after the READ bit is reset to a ’0'. Setting the Clock Bit D7 of the Control Register (8h) is the WRITE bit. Setting the WRITE bit to a `1', like the READ bit, halts updates to the TIMEKEEPER registers. The user can then load them with the correct day, date, and time data in 24 hour BCD format (see Table 13). Resetting the WRITE bit to a `0' then transfers the values of all time registers (Fh-9h, 1h) to the actual TIMEKEEPER counters and allows normal opera- tion to resume. After the WRITE bit is reset, the next clock update will occur one second later. Note: Upon power-up following a power failure, the READ bit will automatically be set to a `1'. This will prevent the clock from updating the TIME- KEEPER registers, and will allow the user to read the exact time of the power-down event. Resetting the READ Bit to a `0' will allow the clock to update these registers with the current time. The WRITE Bit will be reset to a `0' upon powerup. Stopping and Starting the Oscillator The oscillator may be stopped at any time. If the de- vice is going to spend a significant amount of time on the shelf, the oscillator can be turned off to min- imize current drain on the battery. The STOP bit is located at Bit D7 within the Seconds Register (9h). Setting it to a ’1' stops the oscillator. When reset to a ’0', the M48T212A oscillator starts within one sec- ond. Note: It is not necessary to set the WRITE bit when setting or resetting the FREQUENCY TEST bit (FT) or the STOP bit (ST). SETTING ALARM CLOCK REGISTERS Address locations 6h-2h contain the alarm settings. The alarm can be configured to go off at a pre- scribed time on a specific month, date, hour, minute, or second or repeat every year, month, day, hour, minute, or second. It can also be pro- grammed to go off while the M48T212A is in the battery back-up to serve as a system wake-up call. Bits RPT5-RPT1 put the alarm in the repeat mode of operation. Table 12 shows the possible configu- rations. Codes not listed in the table default to the once per second mode to quickly alert the user of an incorrect alarm setting. When the clock information matches the alarm clock settings based on the match criteria defined by RPT5-RPT1, the AF (Alarm Flag) is set. If AFE (Alarm Flag Enable) is also set, the alarm condition activates the IRQ/FT pin. The IRQ/FT output is cleared by a read to the Flags register as shown in Figure 9. A subsequent read of the Flags register will reset the Alarm Flag (D6; Register 0h). The IRQ/FT pin can also be activated in the battery back-up mode. The IRQ/FT will go low if an alarm occurs and both ABE (Alarm in Battery Back-up Mode Enable) and AFE are set. The ABE and AFE bits are reset during power-up, therefore an alarm generated during power-up will only set AF. The user can read the Flag Register at system boot-up to determine if an alarm was generated while the M48T212A was in the deselect mode during pow- er-up. Figure 10 illustrates the back-up mode alarm timing. |
|
|
Enlace URL |
| ¿ALLDATASHEET es útil para Ud.? [ DONATE ] |
Todo acerca de Alldatasheet | Publicidad | Contáctenos | Política de Privacidad | Enlace a la hoja de datos | Intercambio de Enlaces | Lista de Fabricantes All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |