Descripción Electrónicos  16-BIT, 500 MSPS 2?? INTERPOLATING DUAL-CHANNEL DIGITAL-TO-ANALOG CONVERTER (DAC)
PDF  79 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
Fabricante Electrónico  TI [Texas Instruments]
Página de inicio  http://www.ti.com
Logo TI - Texas Instruments

DAC5687IPZP Datasheet(HTML) 62 Page - Texas Instruments

Back Button DAC5687IPZP Datasheet HTML 58Page - Texas Instruments DAC5687IPZP Datasheet HTML 59Page - Texas Instruments DAC5687IPZP Datasheet HTML 60Page - Texas Instruments DAC5687IPZP Datasheet HTML 61Page - Texas Instruments DAC5687IPZP Datasheet HTML 62Page - Texas Instruments DAC5687IPZP Datasheet HTML 63Page - Texas Instruments DAC5687IPZP Datasheet HTML 64Page - Texas Instruments DAC5687IPZP Datasheet HTML 65Page - Texas Instruments DAC5687IPZP Datasheet HTML 66Page - Texas Instruments Next Button
Zoom Inzoom in Zoom Outzoom out
 62 / 79 page
background image
www.ti.com
(a) X2 Mode
(b) X4L Mode
fDAC − MHz
0
10
20
30
40
50
60
70
80
90
0
100
200
300
400
500
G032
fDAC/2
fDAC − MHz
0
10
20
30
40
50
60
70
80
90
100
0
100
200
300
400
500
G033
fDAC/2
fDAC/4
(c) X4 Mode
(d) X8 Mode
fDAC − MHz
0
10
20
30
40
50
60
70
80
90
100
0
100
200
300
400
500
G034
fDAC/2
fDAC/4
fDAC x 3/4
fDAC − MHz
0
10
20
30
40
50
60
70
80
90
100
0
100
200
300
400
500
G035
fDAC/2
fDAC/4
fDAC x 3/4
fDAC/8
fDAC x 7/8
DAC5687
SLWS164E – FEBRUARY 2005 – REVISED SEPTEMBER 2006
Figure 73 and Figure 74 show the typical worst-case spurious signal amplitudes vs fDAC for a signal frequency
fSIG = 11 × fDAC/32 in each mode for PLL on (PLL clock mode) and PLL off (external and dual-clock modes).
Each spurious signal (fDAC/2, fDAC/4 and fDAC/8) has its own curve. The spurious signal amplitudes can then be
adjusted for the exact signal frequency fSIG by applying the amplitude adjustment factor shown in Figure 75. The
amplitude adjustment factor is the same for each spurious signal (fDAC/2, fDAC/4, and fDAC/8) and is normalized for
fSIG = 11 × fDAC/32.
Figure 73. Clock-Related Spurious Signal Amplitude With PLL Off for fSIG = 11 × fDAC / 32
62
Submit Documentation Feedback
Copyright © 2005–2006, Texas Instruments Incorporated
Product Folder Link(s): DAC5687



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79


Datasheet Descarga

Go To PDF Page


Enlace URL



¿ALLDATASHEET es útil para Ud.?  [ DONATE ] 

Todo acerca de Alldatasheet   |   Publicidad   |   Contáctenos   |   Política de Privacidad   |   Enlace a la hoja de datos    |   Intercambio de Enlaces   |   Lista de Fabricantes
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com