| Motor de Búsqueda de Datasheet de Componentes Electrónicos |
|
CTS9513API-2 Datasheet(PDF) 20 Page - List of Unclassifed Manufacturers |
|
|
|||||||||||||||||||||||||||||
CTS9513API-2 Datasheet(HTML) 20 Page - List of Unclassifed Manufacturers |
|
20 / 28 page ![]() Celeritous Technical Services Corp 800.687.6510 / 806.793.0708 3308 34th St FAX 806.793.0710 Lubbock, Texas 79410 http://www.celeritous.com SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE Copyright 2000 Celeritous Technical Services Corp 20 Rev E Tuesday, September 25, CTS9513-2 5 Chan 16 bit 20MHz Counter/Timer MODE N SOFTWARE TRIGGERED STROBE WITH LEVEL GATING AND HARDWARE RETRIGGERING In Mode N, once ARMed, the counter is active only as long at the selected Gate line is asserted. Counting begins only after the gate line is asserted after the counter is ARMed. If the Gate line remains asserted the counter will count to TC, reload automatically from the load register and disarm itself until receipt of a new ARM command. If the gate is deasserted prior to the counter reaching TC the counter will halt. When the Gate line is reasserted on a halted counter, the count value is transferred to the Hold register and the next valid count source edge will cause the counter to reload from the Load register and begin counting again, effectively retriggering the counter as shown in Figure 22. One application of this mode is to measure the delay between two successive gate edges by reading the remainder count value from the hold register. SOURCE WR DATA ARM COMMAND GATE COUNT VALUE TC OUTPUT TOGGLE OUTPUT L-1 L-2 ... N+1 N L L-1 L-2 ... 1 L L-1 COUNTER MODE N WAVEFROMS Figure 22 - CTS9513 Counter Mode N Representative Waveforms SOURCE WR DATA ARM COMMAND GATE COUNT VALUE TC OUTPUT TOGGLE OUTPUT L-1 L-2 ... N+1 N L L-1 L-2 ... 1 L L-1 COUNTER MODE O WAVEFORMS Figure 23 - CTS9513 Counter Mode O Representative Waveforms MODE O SOFTWARE TRIGGERED STROBE WITH EDGE GATING AND HARDWARE RETRIGGERING Mode O is similar to Mode N in that the counter must be ARMed and a valid Gate edge must be received to start the counter. Unlike most other modes, however, each time a valid gate edge is received prior to the counter reaching TC will cause the counter to be retriggered by reloading the counter from the load register on the first valid source edge following a valid gate edge. If the counter is allowed to reach TC is automatically reloads from the Load register and disarms itself. The counter is insensitive to gate edges while disarmed and while counting. The counter is sensitive only to a valid gate edge while counting. |
|
Enlace URL |
| ¿ALLDATASHEET es útil para Ud.? [ DONATE ] |
Todo acerca de Alldatasheet | Publicidad | Contáctenos | Política de Privacidad | Enlace a la hoja de datos | Intercambio de Enlaces | Lista de Fabricantes All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |