| Motor de Búsqueda de Datasheet de Componentes Electrónicos |
|
CTS9513API-2 Datasheet(PDF) 4 Page - List of Unclassifed Manufacturers |
|
|
|||||||||||||||||||||||||||||
CTS9513API-2 Datasheet(HTML) 4 Page - List of Unclassifed Manufacturers |
|
4 / 28 page ![]() Celeritous Technical Services Corp 800.687.6510 / 806.793.0708 3308 34th St FAX 806.793.0710 Lubbock, Texas 79410 http://www.celeritous.com SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE Copyright 2000 Celeritous Technical Services Corp 4 Rev E Tuesday, September 25, CTS9513-2 5 Chan 16 bit 20MHz Counter/Timer On power-up, the data bus is configured for 8 bit transfers. The data bus may be reconfig- ured for 16 bit by programming Master Mode register Bit 13. If D8-15 are not used they should be pulled up. !CS (Chip Select Input) The chip select line is an active low I/O control signal used to enable the device for read and write operations. !WR (Write Input) The write line is an active low I/O control signal which is used to transfer information from the data bus to one of the internal command or data registers. !RD (Read Input) The read line is an active low I/O control signal which is used to transfer information from one of the internal data or command registers to the data bus. C/!D (Control/Data Port Select Input) The C/D line is used in conjunction with the CS, RD, and WR to select which internal command or data register is being written to or read from. The C/D line selects between the command and data register sets as summarized in Table 3 FUNCTIONAL DESCRIPTION SYSTEM LEVEL The CTS9513 is addressed by the external system through two address locations. Counter and com- mand data are written to individual counters through a sequence of indirectly addressing the internal com- mand or data register through the command port address, followed by a write to the data port address which points to the indirectly addressed register location. Data is transferred through either two 8 bit transfers or a single 16 bit transfer. Pointer sequencing for 8 bit transfers is automatic and is transferred as least significant byte first, most significant byte second. Rapid programming of the CTS9513 may be accomplished by use of the auto-increment feature of the data pointer. This feature is enabled by setting Master Mode Register bit 14 (MM14). When enabled, the data pointer may be sequenced through a single counter group, all counter group registers, all counter group Hold registers only, or just the control group registers. INTERNAL CONFIGURATION Overview A simplified block diagram of the CTS9513 is shown in Figure 4. This diagram shows the major device elements consisting of: • five counter groups, • internal frequency prescaler which divides down the primary external clock source from clock input X2, • external FOUT clock prescalers which provide prescaled or divided outputs from a variety of sources, • the Bus interface, • Master mode register and • the status register. Not shown are the extended set registers, power-on reset circuitry or internal control lines. The counter group block diagrams are shown in Figures 5 and 6. Counter groups 1 and 2 as shown in Figure 5 have an additional programmable alarm register and 16 bit comparator for implementation of time-of-day and alarm functions. Counter Groups All of the counter groups have a 16 bit counter and four programmable registers. The primary and auxiliary counter mode register controls the count source, gating and counting modes, input and output polarities, binary or BCD counting and other parameters. Load Register The Load register is the primary register used for storing count-up or count-down values which may be automatically reloaded into the counter for repetitive counting. Hold Register The Hold register may be used for storing the instantaneous count value without disturbing the count process for reading by the host system. It may also be used in certain count modes for storing alternate count values and alternately counting the load and hold register values to generate complex waveforms. Counter Outputs Each of the counters has a single dedicated output pin which is programmable for polarity, tri-state, low-Z to ground and a variety of output modes as described later. This flexibility allows operation in a variety of bus and processor architectures. Source Inputs Each counter group may be programmed for a variety of count sources including any of the five source input lines, any of the internal prescaler outputs or |
|
Enlace URL |
| ¿ALLDATASHEET es útil para Ud.? [ DONATE ] |
Todo acerca de Alldatasheet | Publicidad | Contáctenos | Política de Privacidad | Enlace a la hoja de datos | Intercambio de Enlaces | Lista de Fabricantes All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |