30 / 52 page ![]() REV. C –30– ADT7463 PWM1 CONFIGURATION (REG. 0x5C) <2:0> SPIN These bits control the start-up timeout for PWM1. 000 = No Startup Timeout 001 = 100 ms 010 = 250 ms (default) 011 = 400 ms 100 = 667 ms 101 = 1 s 110 = 2 s 111 = 4 s PWM2 CONFIGURATION (REG. 0x5D) <2:0> SPIN These bits control the start-up timeout for PWM2. 000 = No Startup Timeout 001 = 100 ms 010 = 250 ms (default) 011 = 400 ms 100 = 667 ms 101 = 1 s 110 = 2 s 111 = 4 s PWM3 CONFIGURATION (REG. 0x5E) <2:0> SPIN These bits control the start-up timeout for PWM3. 000 = No Startup Timeout 001 = 100 ms 010 = 250 ms (default) 011 = 400 ms 100 = 667 ms 101 = 1 s 110 = 2 s 111 = 4 s Disabling Fan Start-Up Timeout Although fan start-up makes fan spin-ups much quieter than fixed-time spin-ups, the option exists to use fixed spin-up times. Bit 5 (FSPDIS) = 1 in Configuration Register 1 (Reg. 0x40) disables the spin-up for two TACH pulses. Instead, the fan spins up for the fixed time as selected in Registers 0x5C to 0x5E. PWM Logic State The PWM outputs can be programmed high for 100% duty cycle (noninverted) or low for 100% duty cycle (inverted). PWM1 Configuration (Reg. 0x5C) <4> INV 0 = Logic High for 100% PWM Duty Cycle 1 = Logic Low for 100% PWM Duty Cycle PWM2 Configuration (Reg. 0x5D) <4> INV 0 = Logic High for 100% PWM Duty Cycle 1 = Logic Low for 100% PWM Duty Cycle PWM3 Configuration (Reg. 0x5E) <4> INV 0 = Logic High for 100% PWM Duty Cycle 1 = Logic Low for 100% PWM Duty Cycle PWM Drive Frequency The PWM drive frequency can be adjusted for the application. Registers 0x5F to 0x61 configure the PWM frequency for PWM1 to PWM3, respectively. PWM1 FREQUENCY REGISTERS (REG. 0x5F to 0x61) <2:0> FREQ 000 = 11.0 Hz 001 = 14.7 Hz 010 = 22.1 Hz 011 = 29.4 Hz 100 = 35.3 Hz (Default) 101 = 44.1 Hz 110 = 58.8 Hz 111 = 88.2 Hz Fan Speed Control The ADT7463 can control fan speed using two different modes. The first is automatic fan speed control mode. In this mode, fan speed is automatically varied with temperature and without CPU intervention, once initial parameters are set up. The advantage of this is in the case of the system hanging, the user is guaranteed that the system is protected from overheating. The automatic fan speed control incorporates a feature called dynamic TMIN calibra- tion. This feature reduces the design effort required to program the automatic fan speed control loop. For more information and how to program the automatic fan speed control loop and dynamic TMIN calibration, see the AN-613 Programming the Automatic Fan Speed Control Loop application note (www.analog.com/ UploadedFiles/Application_Notes/331085006AN613_0.pdf). The second fan speed control method is manual fan speed control which is described in the next paragraph. Manual Fan Speed Control The ADT7463 allows the duty cycle of any PWM output to be manually adjusted. This can be useful if users wish to change fan speed in software or want to adjust PWM duty cycle output for test purposes. Bits <7:5> of Registers 0x5C to 0x5E (PWM Configuration) control the behavior of each PWM output. PWM CONFIGURATION (REG. 0x5C to 0x5E) <7:5> BHVR 111 = Manual Mode Once under manual control, each PWM output may be manually updated by writing to Registers 0x30 to 0x32 (PWMx current duty cycle registers). Programming the PWM Current Duty Cycle Registers The PWM current duty cycle registers are 8-bit registers that allow the PWM duty cycle for each output to be set anywhere from 0% to 100% in steps of 0.39%. The value to be programmed into the PWMMIN register is given by Value Decimal PWMMIN () = 0.39 Example 1: For a PWM duty cycle of 50%, Value (Decimal) = 50/0.39 = 128 Decimal Value = 128 decimal or 0x80. Example 2: For a PWM duty cycle of 33%, Value (Decimal) = 33/0.39 = 85 Decimal Value = 85 Decimal or 0x54. PWM DUTY CYCLE REGISTERS Reg. 0x30 PWM1 Duty Cycle = 0xFF (100% Default) Reg. 0x31 PWM2 Duty Cycle = 0xFF (100% Default) Reg. 0x32 PWM3 Duty Cycle = 0xFF (100% Default) Rev. 4 | Page 30 of 52 | www.onsemi.com |
|
Enlace URL |
| ¿ALLDATASHEET es útil para Ud.? [ DONATE ] |
Todo acerca de Alldatasheet | Publicidad | Contáctenos | Política de Privacidad | Enlace a la hoja de datos | Intercambio de Enlaces | Lista de Fabricantes All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |