28 / 126 page ![]() MPC8535E PowerQUICC™ III Integrated Processor Hardware Specifications, Rev. 2 Input Clocks Freescale Semiconductor 28 2.4 Input Clocks 2.4.1 System Clock Timing Table 6 provides the system clock (SYSCLK) AC timing specifications for the MPC8535E. 2.4.2 PCI Clock Timing When the PCI controller is configured for asynchronous operation, the reference clock for the PCI controller is not the SYSCLK input, but instead the PCI_CLK. Table 7 provides the PCI reference clock AC timing specifications for the MPC8535E. 2.4.3 Real Time Clock Timing The RTC input is sampled by the platform clock (CCB clock). The output of the sampling latch is then used as an input to the counters of the PIC and the TimeBase unit of the e500. There is no jitter specification. The minimum pulse width of the RTC signal should be greater than 2x the period of the CCB clock. That is, minimum clock high time is 2 × t CCB, and minimum clock low time is 2 × t CCB. There is no minimum RTC frequency; RTC may be grounded if not needed. Table 6. SYSCLK AC Timing Specifications At recommended operating conditions (see Table 2) with OVDD = 3.3 V ± 165 mV. Parameter/Condition Symbol Min Typical Max Unit Notes SYSCLK frequency fSYSCLK 33 — 133 MHz 1 SYSCLK cycle time tSYSCLK 7.5 — 30 ns — SYSCLK rise and fall time tKH, tKL 0.61.0 2.1ns 2 SYSCLK duty cycle tKHK/tSYSCLK 40 — 60 % — SYSCLK jitter — — — +/-150 ps 3, 4 Notes: 1. Caution: The CCB clock to SYSCLK ratio and e500 core to CCB clock ratio settings must be chosen such that the resulting SYSCLK frequency, e500 (core) frequency, and CCB clock frequency do not exceed their respective maximum or minimum operating frequencies. See Section 2.23.2, “CCB/SYSCLK PLL Ratio,” and Section 2.23.3, “e500 Core PLL Ratio,” for ratio settings. 2. Rise and fall times for SYSCLK are measured at 0.6 V and 2.7 V. 3. The SYSCLK driver’s closed loop jitter bandwidth should be <500 kHz at -20 dB. The bandwidth must be set low to allow cascade-connected PLL-based devices to track SYSCLK drivers with the specified jitter. 4. For spread spectrum clocking, guidelines are +0% to -1% down spread at a modulation rate between 20 KHz and 60 KHz on SYSCLK. Table 7. PCICLK AC Timing Specifications At recommended operating conditions (see Table 2) with OVDD = 3.3 V ± 165 mV. Parameter/Condition Symbol Min Typical Max Unit Notes PCICLK frequency fPCICLK 33 — 66 MHz — PCICLK cycle time tPCICLK 15 — 30 ns — PCICLK rise and fall time tKH, tKL 0.61.0 2.1ns 1 PCICLK duty cycle tKHK/tPCICLK 40 — 60 % — Notes: 1. Rise and fall times for PCICLK are measured at 0.6 V and 2.7 V. |
|
Enlace URL |
| ¿ALLDATASHEET es útil para Ud.? [ DONATE ] |
Todo acerca de Alldatasheet | Publicidad | Contáctenos | Política de Privacidad | Enlace a la hoja de datos | Intercambio de Enlaces | Lista de Fabricantes All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |