160 / 356 page ![]() µPD17704, 17705, 17707, 17708, 17709 160 Figure 13-9. Timing Chart As shown in Figure 13-9, the program is started from address 0000H because the internal 10-Hz pulse rises when supply voltage VDD is first applied. When the BTM0CY flag is detected at point A, it is judged that the BTM0CY flag is reset (to 0) and that a power failure (power-ON reset) has occurred because the power has just been applied. Therefore, “processing C” is executed, and the BTM0CY flag setting pulse is set to 100 ms. Because the content of the BTM0CY flag is read once at point A, the BTM0CY flag will be set to 1 every 100 ms. Next, even if the CE pin goes low at point B and high at point C, the program counts up the watch timer while executing “processing B”, unless the clock stop instruction is executed. At point C, because the CE pin goes high, CE reset is effected at point D at which the BTM0CY flag setting pulse rises next time, and the program is started from address 0000H. When the BTM0CY flag is detected at point E at this time, it is set to 1. Therefore, this is judged to be a back up (CE reset). As is evident from the above figure, unless the watch is updated by 100 ms at point E, the watch is delayed by 100 ms each time CE reset is effected. If processing A takes longer than 100 ms when a power failure is detected at point E, the setting of the BTM0CY flag is overlooked two times. Therefore, processing A must be completed within 100 ms. The above description also applies when the BTM0CY flag setting pulse is set to 50, 20, or 10 ms. Therefore, the BTM0CY flag must be detected for power failure detection within the BTM0CY flag setting time after the program has been started from address 0000H. A Power-ON reset Start from address 0 CE reset Start from address 0 Application of supply voltage BTM0CY flag detected C 5 V VDD CE BTM0CY flag setting pulse (10 Hz) BTM0CY flag Program processing Program instruction 0 V H L H L 1 0 BB B B B BBB B B <3> Watch UP <3> Watch UP <3> Watch UP <3> <3> <1> Watch UP <3> <3> <3> <3> <3> <1> A Updates watch timer because setting of BTM0CY flag (to 1) is detected Point A Point B Point C Point D Point E |
|
Enlace URL |
| ¿ALLDATASHEET es útil para Ud.? [ DONATE ] |
Todo acerca de Alldatasheet | Publicidad | Contáctenos | Política de Privacidad | Enlace a la hoja de datos | Intercambio de Enlaces | Lista de Fabricantes All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |