44 / 72 page ![]() ADE7758 Data Sheet Rev. E | Page 44 of 72 START STEP 1 STEP 1A ENABLE APCF AND VARCF PULSE OUTPUTS STEP 2 CLEAR GAIN REGISTERS: xWG, xVAG, xVARG SELECT VA FOR VARCF OUTPUT CFNUM/VARCFNUM SET TO CALCULATE VALUES? NO YES ALL PHASES VA AND WATT GAIN CAL? YES NO STEP 3 SET UP PULSE OUTPUT FOR PHASE A, B, OR C STEP 5 SET UP SYSTEM FOR ITEST,VNOM PF = 1 STEP 6 MEASURE % ERROR FOR APCF AND VARCF STEP 7 CALCULATE AND WRITE TO xWG, xVAG CALCULATE Wh/LSB AND VAh/LSB CONSTANTS SET CFNUM/VARCFNUM AND CFDEN/VARCFDEN TO CALCULATED VALUES STEP 4 END ALL PHASES VAR GAIN CALIBRATED? YES NO SELECT VAR FOR VARCF OUTPUT STEP 3 SET UP PULSE OUTPUT FOR PHASE A, B, OR C VARCFNUM/ VARCFDEN SET TO CALCULATED VALUES? NO YES STEP 5 SET UP SYSTEM FOR ITEST,VNOM PF = 0, INDUCTIVE STEP 6 MEASURE % ERROR FOR VARCF STEP 7 CALCULATE AND WRITE TO xVARG CALCULATE VARh/LSB CONSTANT SET VARCFNUM/VARCFDEN TO CALCULATED VALUES STEP 4 SELECT PHASE A, B, ORCFOR LINE PERIOD MEASUREMENT Figure 78. Gain Calibration Using Pulse Output Step 1: Enable the pulse output by setting Bit 2 of the OPMODE register (0x13) to Logic 0. This bit enables both the APCF and VARCF pulses. Step 1a: VAR and VA share the VARCF pulse output. WAVMODE[7], Address (0x15), should be set to choose between VAR or VA pulses on the output. Setting the bit to Logic 1 selects VA. The default is Logic 0 or VARCF pulse output. Step 2: Ensure the xWG/xVARG/xVAG are zero. Step 3: Disable the Phase B and Phase C contribution to the APCF and VARCF pulses. This is done by the TERMSEL[2:4] bits of the COMPMODE register (0x16). Setting Bit 2 to Logic 1 and Bit 3 and Bit 4 to Logic 0 allows only Phase A to be included in the pulse outputs. Select Phase A, Phase B, or Phase C for a line period measurement with the FREQSEL[1:0] bits in the MMODE register (0x14). For example, clearing Bit 1 and Bit 0 selects Phase A for line period measurement. |
|
Enlace URL |
| ¿ALLDATASHEET es útil para Ud.? [ DONATE ] |
Todo acerca de Alldatasheet | Publicidad | Contáctenos | Política de Privacidad | Enlace a la hoja de datos | Intercambio de Enlaces | Lista de Fabricantes All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |