54 / 72 page ![]() ADE7758 Data Sheet Rev. E | Page 54 of 72 0 0.088 2 MHz 10 54.64 4 0.161 29 = − = × × × = AWATTOS The low-pass filter used to obtain the rms measurements is not ideal; therefore, it is recommended to synchronize the readings with the zero crossings of the voltage waveform and to average a few measurements when reading the rms registers. Calibration of IRMS and VRMS Offset IRMSOS and VRMSOS are used to cancel noise and offset contributions from the inputs. The calibration method is the same whether calibrating using the pulse outputs or line accumulation. Reading the registers is required for this calibration because there is no rms pulse output. The rms offset calibration should be performed before VAGAIN calibration. The rms offset calibration also removes offset from the VA calculation. For this reason, no VA offset register exists in the ADE7758. The ADE7758 IRMS measurement is linear over a 500:1 range, and the VRMS measurement is linear over a 20:1 range. To measure the voltage VRMS offset (xVRMSOS), measure rms values at two different nonzero current levels, for example, VNOM and VFULLSCALE/20. To measure the current rms offset (IRMSOS), measure rms values at two different nonzero current levels, for example, ITEST and IFULLSCALE/500. This translates to two test conditions: ITEST and VNOM, and IFULLSCALE/500 and VFULLSCALE/20. Figure 85 shows a flowchart for calibrating the rms measurements. STEP 1 SET CONFIGURATION REGISTERS FOR ZERO CROSSING ON ALL PHASES STEP 2 SET INTERRUPT MASK FOR ZERO CROSSING ON ALL PHASES STEP 3 STEP 4 READ RMS REGISTERS STEP 5 WRITE TO xVRMSOS xIRMSOS SET UP SYSTEM FOR ITEST,VNOM SET UP SYSTEM FOR IFULLSCALE/500, VFULLSCALE/20 START TESTED ALL PHASES? YES NO TESTED ALL CONDITIONS? 1 2 STEP 4A CHOOSE N n= 0 STEP 4D READ xIRMS xVRMS STEP 4E CALCULATE THE AVERAGE OF N SAMPLES STEP 4B RESET INTERRUPT STATUS REGISTER END n=n+1 n= N? NO YES YES NO STEP 4C INTERRUPT? Figure 85. RMS Calibration Routine |
|
Enlace URL |
| ¿ALLDATASHEET es útil para Ud.? [ DONATE ] |
Todo acerca de Alldatasheet | Publicidad | Contáctenos | Política de Privacidad | Enlace a la hoja de datos | Intercambio de Enlaces | Lista de Fabricantes All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |