301 / 356 page ![]() 301 µPD17704, 17705, 17707, 17708, 17709 20.4 Device Operation in Halt and Clock Stop Status Table 20-1 shows the operations of the CPU and peripheral hardware units in the halt and clock stop status. In the halt status, all the peripheral hardware units continue the normal operation until instruction execution is stopped. In the clock stop status, all the peripheral hardware units stop operation. The control registers that control the operations of the peripheral hardware units operate normally (not initialized) in the halt status, but are initialized to specified values when the clock stop instruction is executed. In other words, all peripheral hardware continues the operation specified by the control register in the halt status, and the operation is determined by the initialized value of the control register in the clock stop status. For the values of the control registers in the clock stop status, refer to 8. REGISTER FILE (RF). Table 20-1. Device Operation in Halt and Clock Stop Status Peripheral Hardware Status Halt Clock stop Program counter Stops at address of HALT instruction Stops at address of STOP instruction System register Retained Retained Peripheral register Retained Partly initializedNote 1 Control register Retained Partly initializedNote 1 Timer Normal operation Operation stops PLL frequency synthesizer Normal operationNote 2 Operation stops A/D converter Normal operation Operation stops D/A converter Normal operation Stops operation and used as general- purpose output port Serial interface Stops operation when internal clock (master) Stops operation and used as general- is selected and continues operation when purpose I/O port external clock (slave) is selected Frequency counter Normal operation Stops operation and used as general- purpose input port BEEP output Normal operation Stops operation and used as general- purpose I/O port General-purpose I/O port Normal operation Retained General-purpose input port Normal operation Input port General-purpose output port Normal operation Retains output latch Notes 1. For the value to which these registers are initialized, refer to 5. SYSTEM REGISTER (SYSREG) and 8. REGISTER FILE (RF). 2. The PLL frequency synthesizer is automatically disabled by the low level input to the CE pin. 20.5 Cautions on Processing of Each Pin in Halt and Clock Stop Status The halt status is used to reduce the current consumption when, say, only the watch is used. The clock stop function is used to reduce the current consumption of the device to only use the data memory. Therefore, the current consumption must be reduced as much as possible in the halt status or clock stop status. At this time, the current consumption significantly varies depending on the status of each pin, and the points shown in Table 20-2 must be noted. |
|
Enlace URL |
| ¿ALLDATASHEET es útil para Ud.? [ DONATE ] |
Todo acerca de Alldatasheet | Publicidad | Contáctenos | Política de Privacidad | Enlace a la hoja de datos | Intercambio de Enlaces | Lista de Fabricantes All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |