Back Button H8S/2114R Datasheet HTML 819Page - Renesas Technology Corp H8S/2114R Datasheet HTML 820Page - Renesas Technology Corp H8S/2114R Datasheet HTML 821Page - Renesas Technology Corp H8S/2114R Datasheet HTML 822Page - Renesas Technology Corp H8S/2114R Datasheet HTML 823Page - Renesas Technology Corp H8S/2114R Datasheet HTML 824Page - Renesas Technology Corp H8S/2114R Datasheet HTML 825Page - Renesas Technology Corp H8S/2114R Datasheet HTML 826Page - Renesas Technology Corp H8S/2114R Datasheet HTML 827Page - Renesas Technology Corp Next Button
Zoom Inzoom in Zoom Outzoom out
 823 / 1038 page
background image
Section 21 Flash Memory (0.18-
µm F-ZTAT Version)
Rev. 3.00 Jul. 14, 2005 Page 775 of 986
REJ09B0098-0300
(l)
Programming
There is an entry point for the programming program in the area from the start address of a
download destination specified by FTDAR
+ 16 bytes. The subroutine is called and programming
is executed by using the following steps.
MOV.L
#DLTOP+16,ER2
;
Set entry address to ER2
JSR
@ER2
;
Call programming routine
NOP
• The general registers other than R0L are saved in the programming program.
• R0L is a return value of the FPFR parameter.
• Since the stack area is used in the programming program, a 128-byte stack area at the
maximum must be allocated in RAM.
(m) The return value in the programming program, FPFR (general register R0L) is
determined.
(n)
Determine whether programming of the necessary data has finished.
If more than 128 bytes of data are to be programmed, specify FMPAR and FMPDR in 128-byte
units, and repeat steps (l) to (n). Increment the programming destination address by 128 bytes and
update the programming data pointer correctly. If an address that has already been programmed is
written to again, not only will a programming error occur, but also flash memory will be damaged.
(o)
After programming finishes, clear FKEY and specify software protection.
If this LSI is restarted by a reset immediately after user MAT programming has finished, secure a
reset period (period of
RES = 0) of 100 µs which is longer than normal.



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100  ...More


Datasheet Descarga

Go To PDF Page


Enlace URL



¿ALLDATASHEET es útil para Ud.?  [ DONATE ] 

Todo acerca de Alldatasheet   |   Publicidad   |   Contáctenos   |   Política de Privacidad   |   Enlace a la hoja de datos    |   Intercambio de Enlaces   |   Lista de Fabricantes
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com